RELIABLE API-936 STUDY NOTES & TEST API-936 RESULT

Reliable API-936 Study Notes & Test API-936 Result

Reliable API-936 Study Notes & Test API-936 Result

Blog Article

Tags: Reliable API-936 Study Notes, Test API-936 Result, Latest API-936 Test Pass4sure, Latest API-936 Test Objectives, Valid API-936 Dumps Demo

What's more, part of that Prep4sureGuide API-936 dumps now are free: https://drive.google.com/open?id=1RSp10q_ASCYQrWVh_JMCv0V1PkdaqlCu

If you are worried about your exam, just choose us, we will help you pass the exam and strengthen your confidence. API-936 Soft test engine can stimulate the real exam environment, so that you can know the procedure of the exam, and your nerves will be decreased and your confidence will be increased. In addition, API-936 Training Materials are high quality, and they can help you pass the exam just one time. If you fail to pass the exam in your first attempt after using API-936 exam dumps of us, we will give you full refund.

Obtaining the API-936 certification is a valuable achievement for professionals in the refractory industry. It demonstrates a level of knowledge and expertise in the field that is recognized globally, and it can lead to increased job opportunities and higher salaries. Refractory Personnel certification program is administered by the American Petroleum Institute and covers a wide range of topics related to refractory materials, installation, and inspection.

API-936 (Refractory Personnel) Exam covers a wide range of topics related to refractory installation, including the properties and characteristics of refractory materials, the selection and installation of refractory materials, and the inspection and maintenance of refractory linings. API-936 Exam also covers safety practices and procedures, as well as relevant industry codes and standards.

>> Reliable API-936 Study Notes <<

Test API-936 Result | Latest API-936 Test Pass4sure

Our API-936 exam dumps are required because people want to get succeed in IT field by clearing the certification exam. Passing API-936 practice exam is not so easy and need to spend much time to prepare the training materials, that's the reason that so many people need professional advice for API-936 Exam Prep. The API-936 dumps pdf are the best guide for them passing test.

API Refractory Personnel Sample Questions (Q74-Q79):

NEW QUESTION # 74
Which of the following is false per the requirements of API Standard 936?

  • A. Permanent linear change is determined with one 2 in. (50 mm) × 2 in. (50 mm) × 9 in. (230 mm) specimen.
  • B. Density shall be determined using cubes or erosion plates and linear change bars.
  • C. Cold crush strength is determined using two 4-1/2 in. (144 mm) × 4-1/2 in. (114 mm) × 4-1/2 in. (114 mm) cubes.
  • D. Abrasion resistance is determined using two 4-1/2 in. (114 mm) × 4-1/2 in. (144 mm) × 1 in. (25 mm) specimens.

Answer: C

Explanation:
According to API Standard 936, the correct specimen dimensions for cold crush strength testing are:
"Test specimens for cold crushing strength shall be2 in. (50 mm) cubesamples prepared in accordance with ASTM C133."
-API Std 936, Section 6.4.2
This directly invalidates option A, which incorrectly states the specimen size as 4-1/2 inches.
For the other options:
Option B - Density determination:
API 936 states that density shall be measured using the same specimens used for linear change and abrasion resistance:
"Bulk density shall be determined using the same specimens prepared for the linear change and abrasion resistance tests."
-API Std 936, Section 6.4.3
"These specimens include cubes, linear change bars, and erosion plates."
-Appendix A, API Std 936
Option C - Abrasion resistance specimen size:
"Two 4-1/2 in. × 4-1/2 in. × 1 in. (114 mm × 114 mm × 25 mm) specimens shall be prepared for abrasion resistance testing."
-API Std 936, Section 6.4.4
Option D - Permanent linear change specimen size:
"Permanent linear change (PLC) is determined with a bar 2 in. × 2 in. × 9 in. (50 mm × 50 mm × 230 mm) cast in steel molds."
-API Std 936, Section 6.4.1
Therefore, Option A is the only false statement.


NEW QUESTION # 75
Refractories chemically and physically stable at

  • A. Low temperatures
  • B. None of the above
  • C. High temperatures
  • D. Average temperatures

Answer: C


NEW QUESTION # 76
Which of the following statements regarding curing of hydraulic bonded castables is true?

  • A. No part of the lining shall be allowed to air dry more than 3 hours before application of a curing compound
  • B. The membrane curing compound shall burn off at a temperature not less than 500°F (260°C)
  • C. After remaining in place for 24 hours, forms shall be removed and a curing compound applied within 1 hour of form removal
  • D. Apply a manufacturer approved membrane-type curing compound before the surface is dry to the touch

Answer: A

Explanation:
Hydraulic bonded castables, such as those using calcium aluminate cement, cure through ahydration reactionthat requires the presence of water. Premature drying due to wind, sun, or heat can halt the hydration process, weaken the structure, and cause surface cracking. API 936 mandates thatno part of the exposed surface of the castable shall be allowed to dry more than 3 hoursbefore a membrane curing compound is applied.
This statement ensures:
Retention of sufficient surface moisture for ongoing hydration.
Prevention of microcracking, which can later act as stress risers during service.
Uniform strength development across the lining.
The curing compound forms a film that limits evaporation, allowing for continued hydration over the next 24-
48 hours.
Reference:
API Std 936, Section 6.3.2: "No portion of the exposed surface shall be allowed to dry more than 3 h prior to the application of the curing compound." ASTM C309(Referenced Standard): Specifies the performance requirements for curing compounds used in cement-based materials.


NEW QUESTION # 77
Pre-turn around planning means

  • A. At least 12 months prior to the turnaround
  • B. Any of the above
  • C. At least 8 months prior to the turnaround
  • D. At least 6 months prior to the turnaround

Answer: D


NEW QUESTION # 78
The terminology for testing refractory that was sampled during installation in order to confirm that they meet specified physical property standards is called

  • A. None of the above
  • B. Physical property test
  • C. Both of the above
  • D. As - installed testing

Answer: D


NEW QUESTION # 79
......

We deeply know that the pass rate is the most important. As is well known to us, our passing rate has been high; Ninety-nine percent of people who used our API-936 real braindumps have passed their exams and get the certificates. I dare to make a bet that you will not be exceptional. Your test pass rate is going to reach more than 99% if you are willing to use our API-936 Study Materials with a high quality. So it is worthy for you to buy our API-936 practice prep.

Test API-936 Result: https://www.prep4sureguide.com/API-936-prep4sure-exam-guide.html

What's more, part of that Prep4sureGuide API-936 dumps now are free: https://drive.google.com/open?id=1RSp10q_ASCYQrWVh_JMCv0V1PkdaqlCu

Report this page